  thecopyrightandauthorityfortheinterpretationoftheproductsarereservedbymornsun ura_d-30wr2&urb_d-30wr2 2013.03.12-a/0 page1of7 features efficiencyupto90% 4:1wideinputvoltagerange 1500vdcisolation six-sidedmetalshield shortcircuitprotection (automaticrecovery) operating temperature: -40 c to +85 c industrystandardpinout meetcisp22/en55022classa application ura_d-30wr2&urb_d-30wr2 series offer 30wofoutput,wideinputvoltage:9-36vdc 18-75vdc and features 1500vdc isolation, six-sided metal shield,overcurrentandshortcircuitprotection.all models are particularly suitable for industrial, telecommunication,electricpower,testequipmentsa pplications. ura_d-30wr2&urb_d-30wr2 series 30w ,4:1wideinput,isolated®ulated dual/singleoutputdipdc-dcconverter patentprotected rohs partnumbersystem urb2405d-30wr2 product series input voltage output voltage package style rated power selectionguide model input voltage(vdc) output voltage (vdc) outputcurrent(ma) inputcurrent (ma)(typ.) reflected ripple current (ma,typ.) max.capacitive load ( f) efficiency (%,typ.)@max. load nominal (range) max max. min. @max. load @no load URA2405D-30WR2 24 (9-36) 40 5 3000 150 1450 30 30 2000 86 ura2412d-30wr2 12 1250 63 1420 1250 89 ura2415d-30wr2 15 1000 50 680 90 urb2405d-30wr2 5 6000 300 1420 120 6000 88 urb2412d-30wr2 12 2500 125 30 2500 88 urb2415d-30wr2 15 2000 100 1100 90 ura4805d-30wr2 48 (18-75) 80 5 3000 150 730 30 2000 86 ura4812d-30wr2 12 1250 63 730 1250 87 ura4815d-30wr2 15 1000 50 680 87 urb4805d-30wr2 5 6000 300 720 100 6000 88 urb4812d-30wr2 12 2500 125 30 2500 88 urb4815d-30wr2 15 2000 100 1100 89 note: .serieswithsuffix h areheatsinkmounting,forexampleurb2405d-30whr2iswithheatsink,urb2405d-30wr2iswithoutheatsink. iftheapplicationhasahigherrequirementforheatdissipation,youcanchoosemoduleswithheatsink. .absolutemaximumratingwithoutdamageontheconverter,butitisn'trecommended. .fordualoutputconverter,thegivenvalueisthesameforeachoutput. input specifications item testconditions min. typ. max. unit inputsurgevoltage(1sec.max.) 24vdcinput -0.7 -- 50 vdc 48vdcinput -0.7 -- 100 undervoltagelockout nominalinput (24v) modelson -- -- 9 modelsoff 7.8 -- -- nominalinput (48v) modelson -- -- 17.8 modelsoff 16 -- --
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedbymornsun ura_d-30wr2&urb_d-30wr2 2013.03.12-a/0 page2of7 start-uptime -- 10 -- ms ctrl* modelson ctrlleaveopenorconnectttlhighlevel(2.5-12vdc) modelsoff ctrlconnectgndorlowlevel(0-1.2vdc) inputcurrent(modelsoff) -- 1 -- ma inputfilter pi filter note:*thectrlpinvoltageisreferencedtognd. output specifications item testconditions min. typ. max. unit outputvoltageaccuracy -- 1 3 % loadregulation from5%to100%loadinput -- 0.5 1 voltageregulation 100%load,inputvoltagefromlowtohigh -- 0.2 0.5 crossregulation from10%to100%loadinput(dualoutput) -- -- 5 transientresponsedeviation 25%loadstepchange -- 3 5 transientrecoverytime -- 300 500 s temperaturedrift 100%load -- 0.02 -- %/ c ripple&noise* 20mhzbandwidth -- 85 100 mvp-p trim -- 10%vo -- vdc overvoltageprotection 5voutput -- 6.1 -- 12voutput -- 15 -- 15voutput -- 18 -- overcurrentprotection inputvoltagerange -- 150 -- %io shortcircuitprotection hiccup,continual,auto-recovery note:*rippleandnoisetestedby parallelcable method.seedetailedoperationinstructionsattestingofpowerconvertersection,applicationnotes. common specifications item testconditions min. typ. max. unit isolationvoltage input-output,testedfor1minuteandleakagecurrent than1ma 1500 -- -- vdc isolationresistance input-output,testat500vdc 1000 -- -- m isolationcapacitance input-output,100khz/0.1v -- 2000 -- pf switchingfrequency pwmmode -- 400 -- khz mtbf mil-hdbk-217f@25 1000 -- -- khours casematerial aluminumalloy size withoutheatsink 50.8x40.6x11.8 mm withheatsink 50.8x40.6x16.3 weight withoutheatsink -- 50 -- g withheatsink -- 70 -- environmental specifications item testconditions min. typ. max. unit storagehumidity noncondensing 5 -- 95 % operatingtemperature powerderating(above60 ,seefigure3) -40 -- 85 c storagetemperature -55 -- 125 themax.casetemperature operatingtemperaturecurverange -- -- 105 leadtemperature 1.5mmfromcasefor10seconds -- -- 300 cooling freeairconvection emcspecifications emi ce cispr22/en55022classa withoutexternalcircuit /classb externalcircuitrefertofigure1- ? re cispr22/en55022classa withoutexternalcircuit /classb externalcircuitrefertofigure1- ? ems esd iec/en61000-4-2 contact 4kv perf.criteriab rs iec/en61000-4-3 10v/m perf.criteriaa eft iec/en61000-4-4 2kv perf.criteriab externalcircuitrefertofigure1- ? surge iec/en61000-4-5 2kv perf.criteriab externalcircuitrefertofigure1- ?
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedbymornsun ura_d-30wr2&urb_d-30wr2 2013.03.12-a/0 page3of7 cs iec/en61000-4-6 3vr.m.s perf.criteriaa ems voltagedips,short andinterruptions immunity iec/en61000-4-29 0%-70% perf.criteriab emcrecommendedcircuit vin gnd +vo -vo eut load c2 lcm c0 tvs ldm mov fuse c1 c4 vin gnd c3 load 0v vin gnd +vo 0v eut load c2 lcm c0 tvs ldm mov fuse c1 c4 vin gnd c3 ura_d-30wr2 urb_d-30wr2 (figure1) recommendedexternalcircuitparameters: model ura24_d-30wr2 urb24_d-30wr2 ura48_d-30wr2 urb48_d-30wr2 fuse chooseaccordingtopracticalinputcurrent mov 10d560k 10d101k ldm 56 h tvs smcj48a smcj90a c0 120 f/50v 120 f/100v c1 4.7 f/50v 2.2 f/100v lcm 2.2mh fl2d-30-222 c2 4.7 f/50v 2.2 f/100v c3,c4 1nf/2kv note:1.infigure1,part isemsrecommendedexternalcircuit,part isemirecommendedexternalcircuit.chooseaccordingtorequirements. 2.fl2d-30-222istheemcauxiliarycomponentofourcompany. emcrecommendedcircuitpcblayout (figure2)
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedbymornsun ura_d-30wr2&urb_d-30wr2 2013.03.12-a/0 page4of7 emctestwaveform (class b apply circuit) ura4815d-30wr2 ce(positiveline) ura4815d-30wr2 ce(negativeline) urb2405d-30wr2 ce(positiveline) urb2405d-30wr2 ce(negativeline) ura4815d-30wr2 re(horizontal) ura4815d-30wr2 re(vertical) urb2405d-30wr2 re(horizontal) urb2405d-30wr2 re(vertical) product typical curve operating temp( c) o u t p u t p o w e r p e r c e n t ( % ) 0 20 40 60 80 100 120 -40 0 40 85 120 70 60 withoutheatsink with heatsink safe operating area (figure3)
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedbymornsun ura_d-30wr2&urb_d-30wr2 2013.03.12-a/0 page5of7 efficiency vs input voltage curve (full load) 50 55 60 65 70 75 80 85 90 95 100 18243036424854606675 input voltage(v) efficiency(%) ura4815d-30wr2 efficiency vs output load curve (vin=vin-nominal) 0 10 20 30 40 50 60 70 80 90 100 5102030405060708090100 total output current (%) efficiency(%) ura4815d-30wr2 efficiency vs input voltage curve (full load) 50 55 60 65 70 75 80 85 90 95 100 9121518212427303336 input voltage(v) efficiency(%) urb2405d-30wr2 efficiency vs output load curve (vin=vin-nominal) 0 10 20 30 40 50 60 70 80 90 100 5102030405060708090100 total output current (%) efficiency(%) urb2405d-30wr2 dimensions,recommendedfootprint&packaging
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedbymornsun ura_d-30wr2&urb_d-30wr2 2013.03.12-a/0 page6of7 heatsinkassembly&packagediagram testconfigurations inputreflected-ripplecurrenttestsetup inputreflected-ripplecurrentismeasuredwithaninductorlinandcintosimulatesourceimpedance. dc cin lin dc load oscilloscope current probe lin(4.7 h) cin(220 f,esr<1.0 at100khz) trimapplication&trimresistance applicationcircuitfortrim(partinbrokenlineistheinteriorofmodels) 0v r 2 r 1 r 3 v ref r t trim +vo 0v r 2 r 1 r 3 v ref r t trim +vo trim up trim down formulaforresistanceoftrim up: a= vref vo -vref r 1 r= t ar 2 r-a 2 -r 3 down: a= vref vo -vref r 2 r= t ar 1 r-a 1 -r 3 note:leaveopenifnotused.valueforr1,r2,r3,andvrefrefertothebelowtable1 r t :resistanceoftrim.a:user-definedparameter,noactual meanings.vo :thetrimup/downvoltage. trimparameter(table1) vo parameter 5 (vdc) 12 (vdc) 15 (vdc) r1(k ) 2.883 10.971 14.497 r2(k ) 2.864 2.864 2.864 r3(k ) 10 17.8 17.8 vref(v) 2.5 2.5 2.5
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedbymornsun ura_d-30wr2&urb_d-30wr2 2013.03.12-a/0 page7of7 note: 1. min.loadshouldn'tbelessthan5%,otherwiseripplemaybeincreaseddramatically,iftheproductoperatesundermin.load,itmaynotbe guaranteedtomeetallspecificationslisted.operationunderminimumloadwillnotdamagetheconverter. 2. recommendeddualoutputmodelsunbalancedloadis ? 5%,iftheproductoperates> 5%,itmaynotbeguaranteedtomeetallspecifications listed.pleasecontactourtechnicalsupportformoredetails. 3. max.capacitiveloadistestedatinputvoltagerangeandfullload. 4. allspecificationsmeasuredatta=25 c,humidity<75%,nominalinputvoltageandratedoutputloadunlessotherwisespecified. 5. inthisdatasheet,alltestmethodsarebasedonourcorporatestandards. 6. allcharacteristicsareforlistedmodels,andnon-standardmodelsmayperformdifferently.pleasecontactourtechnicalsupportformoredetails. 7. pleasecontactourtechnicalsupportforanyspecificrequirement. 8. specificationsofthisproductaresubjecttochangeswithoutpriornotice. mornsunscience&technologyco.,ltd. address:no.5,kehuist.1,kehuidevelopmentcenter,scienceave.,guangzhousciencecity,luogangdistrict,guangzhou,p.r.china. tel:86-20-38601850 fax:86-20-38601272 e-mail: info@mornsun.cn http://www.mornsun-power.com designconsiderations 1)recommendedcircuit alltheura_d-30wr2&urb_d-30wr2serieshavebeentestedaccordingtothefollowingrecommendedtestcircuitbeforeleaving thefactory(seefigure4). ifyouwanttofurtherdecreasetheinput/outputripple,youcanincreaseacapacitance-valuesproperlyorchoosecapacitorswithlowesr, butthetotalcapacitanceofthefiltercapacitormustnotexceedthemax.capacitiveload. recommendexternalcapacitorseetable2. (figure4) (table2) singlevout vdc cin u f cout u f dual vout vdc cin uf cout* uf 3.3/5 10uf 10uf 5 10uf 10uf 12/15 10uf 4.7uf 12/ 15 10uf 4.7uf note:*foreachoutput 2)itisnotrecommendedtoincreasetheoutputpowercapabilitybyconnectingtwoormoreconvertersinparallel.theproductisnot hot-swappable vin gnd +vo 0v dc cin dc cout cout -vo dual output single output vin gnd +vo 0v dc cin dc cout


▲Up To Search▲   

 
Price & Availability of URA2405D-30WR2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X